Offered By Us is dc Earth Leakage Relay that Works By Measuring Differential Current Between Both the –ve and +ve Current Carrying Conductors. the Dc Earth Leakage Relay Provided By Us is Supplied to Far Flung Areas of the World Through the Wide Spread Network of the Company. umore...
Current rating ( In ):0.03 to 0.1A /0.3 to 1.0A : 110V/220V AC
Cream & Dark Blue : 0.3 to 1.0Ain steps of 0.1A
0.03 to 0.1A / 0.15 to 0.50A : 0.03 to 0.1A in steps of 0.01A
Features Bar graph indication of leakage current Remote reset and test facility Wide range of settings Low burden Principle of Operation: JRC 974 provides earth leakage protection for power systems. The relay operating time is determined by a programmable definite time delay. Themore...
Feature : Short-circuit protection.,Low power consumption.
Unexpected breakdowns in the electricity supply produce very high economic losses. Monitoring and signaling of earth faults is essential in these situations. HBL’s ELM in DC power systems enables quick detection of earth faults to prompt for corrective action. It works on the pmore...
Delivering the best in class products, we ensure that the range is in compliance with the International Norms. We believe in keeping transparency in the transactions and thus we offer an invoice to the clients stating all the necessary details. We undertake both online and offlinmore...
Size: (mm)- 22.5mm width op contacts-1 co aux supply-90-270v acdc mounting-din channel mounting distinctive feature-micro controller based design automanual reset + normal failsafe modes. more...
Special Features • Most compact yet ultra flexible protection relays • Micro controller based True RMS Measurement • Two Tripping ranges in one unit • Two Time delay ranges in one unit • User selectable Normal/Fail safe Modes • User selecmore...
SETTING RANGES : Current Model AVT-ELR-05A : 1A to 8A Model AVT-ELR-06A : 30mA to 300mA Delay Time : 0.3 to 3.0 secS Auxiliary Supply : 185-250 VACIndustrial equipment protection Suitable for low voltage distribution protectionmore...
Earth leakage current give rise to temperature and progressive failure of insulation which leads to operating flash over. It is essential to detect earth leakage current well before they cross threshold limits and isolate the circuit. SYCON 770X Earth leakage Relay continuously dmore...
We are offering sycon-770x earth leakage relay. Earth leakage current give rise to temperature and progressive failure of insulation which leads to operating flash over. It is essential to detect earth leakage current well before they cross threshold limits and isolate the circuimore...
We are offering earth leakage relay, order code current range tripping time sycon 7701 30 ma to 300 ma 0.15 sec to 3 sec sycon 7702 300 ma to 3 a 0.15 sec to 3 sec sycon 7703 1 a to 8 a 0.15 sec to 3 sec display green led for healthy indication red led for trip indication generalmore...
We are offering earth leakage relay with display order code current range tripping time sycon 7721 30 ma to 300 ma 0.15 sec to 3 sec sycon 7722 300 ma to 3 a 0.15 sec to 3 sec sycon 7723 1 a to 8 a 0.15 sec to 3 sec general features solid state wide operating current range. low pmore...
Control panels and switch boards Sensitive environment like chemical plants, Oil refiners Generators, utility power monitoring, Transformers, Motor Mining and control Engineering, Leakage current monitoring in 1 & 3 phase system User selectable trip setting Adjustable set point fmore...
Protection for Control panels and switch boards. Protection for Sensitive environment like chemical plants, Oil refiners. Protection for Mining and control Engineering. more...
Measuring Parameter:Leakage Current Monitoring in 3Ø & 1Ø systems, Electrical Connection: 1Ø-2W, 3Ø-3W, 3Ø-4W, Accuracy:Current : ± 5% of setting , Recovery Time, Trip Delay, Power ON delay: ± 5% of setting + 100, Time Ranges: Power ON Delay : 0.5-99.9 sec , Trip Time Delamore...
We are offering earth leakage relays - 1st relay (1ø, 2-pole, 220v, 50hz.). protection electric shock short circuit up to 10000a over load power wastage degree of protection = ip 20. I2t = class-3. features time interval siren working bye pass audio & video indicator variable idmore...
We are offering earth leakage relays - 1st relay (3ø, 4-pole, 415v, 50hz.). protection electric shock short circuit up to 10000a over load power wastage degree of protection = ip 20. I2t = class-3. features time interval siren working bye pass audio & video indicator variable idmore...
We are offering earth leakage relays - 2nd relay (1ø, 2-pole, 220v, 50hz.). protection electric shock short circuit up to 10000a over load power wastage over voltage neutral return two phashing degree of protection = ip 20. I2t = class-3 features time interval siren working bye more...
Earth leakage current give rise to temperature and progressive failure of insulation which leads to operating flash over. It is essential to detect earth leakage current well before they cross threshold limits and isolate the circuit. SYCON 770X Earth leakage Relay continuously dmore...
An Earth Fault Relay is a safety device used in electrical installations with high earth impedance to prevent shock. It detects small stray voltages on the metal enclosures of electrical equipment, and interrupts the circuit if a dangerous voltage is detected. more...